Abatement Technologies PRED1200 Air Scrubber – 900 CFM, 4-Stage HEPA, 3.5A
$1,666.55 Original price was: $1,666.55.$999.93Current price is: $999.93.
300–900 CFM Variable HEPA Air Scrubber with 4-Stage Filtration and Daisy-Chain Power
The Abatement Technologies PRED1200 adjusts from 300 to 900 CFM, covering spaces up to 9,000 cubic feet at 6 air changes per hour. At maximum speed it draws only 3.5 amps — low enough to daisy-chain up to five units on a single 15-amp circuit. Four filtration stages (MERV4 coarse, MERV8 pleated, optional MERV7 carbon, true HEPA) extend HEPA filter life and address both particulate and VOC contamination in one machine.
Filtration Architecture and Power Specs
- Stage 1 – MERV4 coarse pre-filter — captures large debris and extends the life of downstream stages; replaced during normal maintenance cycles without tools.
- Stage 2 – MERV8 pleated pre-filter — removes medium particles; the hinged rear access door with full-perimeter gasket seals against dirty-air bypass during filter changes.
- Optional Stage 3 – VAPOR-LOCK carbon filter (MERV7) — removes odors and VOCs from mold-damaged structures, fire restoration, and chemical-remediation sites.
- Stage 4 – True HEPA at 99.97% / 0.3 microns — long-life rated filter certified to UL 507 and CAN/CSA C22.2 No. 113.
- 3.5A draw, 5-unit daisy chain — run five PRED1200s from a single 15-amp breaker; critical on large jobsites with limited panel access.
- Upright or horizontal operation, 70 lbs — operates in either orientation to fit low-ceiling crawlspaces, confined HVAC rooms, and standard wall-adjacent placement.
Typical Deployment Environments
Large-scale mold remediation contractors deploy multiple PRED1200 units in daisy-chain configurations across commercial office floors and multi-family residential buildings where circuit availability is limited. Fire-restoration companies use the VAPOR-LOCK carbon filter stage to address smoke and VOC contamination alongside particulate cleanup in the same unit. Water-damage restorers position PRED1200s in horizontal orientation inside crawlspaces and under-slab cavities where upright placement is impossible. Healthcare construction project managers use pairs of PRED1200s as the primary negative-air system on ICRA Category III projects in occupied hospital wings, where the 3.5A draw per unit avoids tripping branch circuits in older facility electrical infrastructure.
Specifications and Certification
| Airflow Range | 300–900 CFM |
|---|---|
| Max Coverage | 9,000 ft³ @ 6 ACH |
| HEPA Efficiency | 99.97% @ 0.3 microns |
| Starting Amps | 3.5 A or less |
| Daisy-Chain Capacity | Up to 5 units per 15 A circuit |
| Dimensions | 22″ × 24″ × 42″ |
| Weight (with filters) | 70 lbs |
| Power Supply | 120 VAC, 60 Hz, 15 A |
| Cabinet Material | TEFGARD polyethylene – UL94HB flame retardant |
| Electrical Certification | NRTL – UL Std. 507 & CAN/CSA C22.2 No. 113 |
| Xactimate Code | AQRS |
Video
Documents
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.

Reviews
There are no reviews yet.